Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Ain IX = application handle from OS_Poll OUT, if call successful: Fc = 0 BHL = pointer to application name (null-terminated) BDE = pointer to application DOR A = CLI-related attributes C = preferred code letter. OUT, if call failed: Fc = 1 A = RC_HAND Registers changed after return: ......../IXIY same AFBCDEHL/.... different |
Notes
CLI-related attributes refer to Application Type Byte 1 in application DOR.
NQ_Khn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Khn OUT: IX = keyboard handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":INP" device instead.
...
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Shn OUT: IX = screen handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":SCR" device instead.
...
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Hhn OUT: IX = null handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":NUL" device instead
...
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Wai OUT: IX = static process handle BCC = dynamic process handle (PID) B = 0 Registers changed after return: A...DEHL/..IY same .FBC..../IX.. different |
...
Notes
- Static process handle is unique to each application. It follows slot number and application order in slot (1-31 for internal slot, 32-63 for slot 1, 64-95 for slot 2, 96-127 for slot 3, 128-255 for installed applications). Index handle is always 1, Pipedream handle is 3...
- Dynamic process handle (PID equivalent) is unique to each suspended or running process (range 2-127, Index PID is always number 1).
NQ_Com
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Com OUT: IX = comms handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":COM" device instead.
...
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Ihn OUT: IX = IN handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":INP" device instead.
...
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Ohn OUT: IX = OUT handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":OUT" device instead.
...
Code Block | ||
---|---|---|
| ||
IN: A = check OZ version required (for example $45 for OZ V4.5) BC = NQ_Voz OUT, if call successful: Fc = 0 Running OZ is equal to or higher than specified version OUT, if call reported incompatible OZ ROM: Fc = 1 A = RC_QUITVOZ ($67$38), OZ version not compatible Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:
if If OS_Nq, NQ_Voz is used on OZ ROM's earlier than V4.5, a standard "Internal Error" popup window is displayed to prompt the user to press ESC (the NQ_Voz doesnt exist).
For OZ V4V5.5 0 and later a similar but more correct window is displayed with "This application requires OZ VX.Y or newer" message if the specified OZ release is newer than what is currently running.
, the "OZ version not compatible" message is displayed as a fatal error using a OS_BYE with A unchanged if Fc = 1.
NQ_Roz
Code Block | ||
---|---|---|
| ||
IN: - OUT: DEBC = OZ revision number Registers changed after return: AF....HL/IXIY same ..BCDE../.... different |
...
Code Block | ||
---|---|---|
| ||
IN: - OUT: Fz = 0, Battery is good Fz = 1, Battery is low Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:Used
Battery low condition is set when under 4.2V. Coma state is entered by NMI when battery voltage falls under 3.2V.
This call is used by system information page in Index.