Code Block |
---|
language | none |
---|
title | NQ_Ain ($8600), Application enquiry (system use only) |
---|
|
IN:
BC = NQ_Ain
IX = application handle from OS_Poll
OUT, if call successful:
Fc = 0
BHL = pointer to application name (null-terminated)
BDE = pointer to application DOR
A = CLI-related attributes
C = preferred code letter.
OUT, if call failed:
Fc = 1
A = RC_HAND
Registers changed after return:
......../IXIY same
AFBCDEHL/.... different |
Notes
CLI-related attributes refer to Application Type Byte 1 in application DOR.
NQ_Khn
Code Block |
---|
language | none |
---|
title | NQ_Khn ($8603), Read keyboard handle |
---|
|
IN: BC = NQ_Khn
OUT: IX = keyboard handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":INP" device instead.
...
Code Block |
---|
language | none |
---|
title | NQ_Shn ($8606), Read screen handle |
---|
|
IN: BC = NQ_Shn
OUT: IX = screen handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":SCR" device instead.
...
Code Block |
---|
language | none |
---|
title | NQ_Nhn ($860C), Read null handle |
---|
|
IN: BC = NQ_Hhn
OUT: IX = null handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":NUL" device instead
...
Code Block |
---|
language | none |
---|
title | NQ_Wai ($860F), Who am I? (system use only) |
---|
|
IN: BC = NQ_Wai
OUT: IX = static process handle
C = dynamic process handle (PID)
B = 0
Registers changed after return:
A...DEHL/..IY same
.FBC..../IX.. different |
- Static process handle is unique to each application. It follows slot number and application order in slot (01-31 for internal slot 0, 32-63 for slot 1, 64-95 for slot 2, 96-127 for slot 3, 128-255 for installed applications). Index handle is always 1, Pipedream handle is 3...
- Dynamic process handle (PID equivalent) is unique to each suspended or running process (range 2-127, Index PID is always number 1).
NQ_Com
Code Block |
---|
language | none |
---|
title | NQ_Com ($8612), Read comms handle |
---|
|
IN: BC = NQ_Com
OUT: IX = comms handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":COM" device instead.
...
Code Block |
---|
language | none |
---|
title | NQ_Ihn ($8615), Read IN handle |
---|
|
IN: BC = NQ_Ihn
OUT: IX = IN handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":INP" device instead.
...
Code Block |
---|
language | none |
---|
title | NQ_Ohn ($8618), Read OUT handle |
---|
|
IN: BC = NQ_Ohn
OUT: IX = OUT handle
Registers changed after return:
A.BCDEHL/..IY same
.F....../IX.. different |
Use ":OUT" device instead.
...
Code Block |
---|
title | NQ_Voz ($861E), Application verifies running OZ version (OZ V4.5 and newer) |
---|
|
IN:
A = check OZ version required (for example $45 for OZ V4.5)
BC = NQ_Voz
OUT, if call successful:
Fc = 0
Running OZ is equal to or higher than specified version
OUT, if call reported incompatible OZ ROM:
Fc = 1
A = RC_QUITVOZ ($67$38), OZ version not compatible
Registers changed after return:
A.BCDEHL/IXIY same
.F....../.... different |
Notes:
if If OS_Nq, NQ_Voz is used on OZ ROM's earlier than V4.5, a standard "Internal Error" popup window is displayed to prompt the user to press ESC (the NQ_Voz doesnt exist).
For OZ V4V5.5 0 and later a similar but more correct window is displayed with "This application requires OZ VX.Y or newer" message if the specified OZ release is newer than what is currently running. , the "OZ version not compatible" message is displayed as a fatal error using a OS_BYE with A unchanged if Fc = 1.
NQ_Roz
Code Block |
---|
title | NQ_Roz ($8621), Read OZ revision number (OZ V4.5 and newer) |
---|
|
IN:
-
OUT:
DEBC = OZ revision number
Registers changed after return:
AF....HL/IXIY same
..BCDE../.... different |
...
Code Block |
---|
title | NQ_Btl ($8624), Read battery status (OZ V4.5 and newer) |
---|
|
IN:
-
OUT:
Fz = 0, Battery is good
Fz = 1, Battery is low
Registers changed after return:
A.BCDEHL/IXIY same
.F....../.... different |
Notes:
Used Battery low condition is set when under 4.2V. Coma state is entered by NMI when battery voltage falls under 3.2V.
This call is used by system information page in Index.