Code Block | ||
---|---|---|
| ||
IN: A = check OZ version required (for example $45 for OZ V4.5) BC = NQ_Voz OUT, if call successful: Fc = 0 Running OZ is equal to or higher than specified version OUT, if call reported incompatible OZ ROM: Fc = 1 A = RC_QUITVOZ ($67$38), OZ version not compatible Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:
if If OS_Nq, NQ_Voz is used on OZ ROM's earlier than V4.5, a standard "Internal Error" popup window is displayed to prompt the user to press ESC (the NQ_Voz doesnt exist).
For OZ V4V5.5 0 and later a similar but more correct window is displayed with "This application requires OZ VX.Y or newer" message if the specified OZ release is newer than what is currently running. , the "OZ version not compatible" message is displayed as a fatal error using a OS_BYE with A unchanged if Fc = 1.
NQ_Roz
Code Block | ||
---|---|---|
| ||
IN: - OUT: DEBC = OZ revision number Registers changed after return: AF....HL/IXIY same ..BCDE../.... different |
...
Code Block | ||
---|---|---|
| ||
IN: - OUT: Fz = 0, Battery is good Fz = 1, Battery is low Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:
Used Battery low condition is set when under 4.2V. Coma state is entered by NMI when battery voltage falls under 3.2V.
This call is used by system information page in Index.