CLI-related attributes refer to Application Type Byte 1 in application DOR.
NQ_Khn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Khn OUT: IX = keyboard handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":INP" device instead.
NQ_Shn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Shn OUT: IX = screen handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":SCR" device instead.
NQ_Phn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Phn OUT: IX = printer indirected handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
NQ_Nhn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Hhn OUT: IX = null handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":NUL" device instead
NQ_Wai
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Wai OUT: IX = static process handle C = dynamic process handle (PID) B = 0 Registers changed after return: A...DEHL/..IY same .FBC..../IX.. different |
Notes
- Static process handle is unique to each application. It follows slot number and application order in slot (1-31 for internal slot, 32-63 for slot 1, 64-95 for slot 2, 96-127 for slot 3, 128-255 for installed applications). Index handle is always 1, Pipedream handle is 3...
- Dynamic process handle (PID equivalent) is unique to each suspended or running process (range 2-127, Index PID is always number 1).
NQ_Com
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Com OUT: IX = comms handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":COM" device instead.
NQ_Ihn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Ihn OUT: IX = IN handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":INP" device instead.
NQ_Ohn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Ohn OUT: IX = OUT handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
Notes
Use ":OUT" device instead.
NQ_Rhn
Code Block | ||||
---|---|---|---|---|
| ||||
IN: BC = NQ_Rhn OUT: IX = printer direct handle Registers changed after return: A.BCDEHL/..IY same .F....../IX.. different |
NQ_Voz
Code Block | ||
---|---|---|
| ||
IN: A = check OZ version required (for example $45 for OZ V4.5) BC = NQ_Voz OUT, if call successful: Fc = 0 Running OZ is equal to or higher than specified version OUT, if call reported incompatible OZ ROM: Fc = 1 A = RC_QUITVOZ ($67$38), OZ version not compatible Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:
if If OS_Nq, NQ_Voz is used on OZ ROM's earlier than V4.5, a standard "Internal Error" popup window is displayed to prompt the user to press ESC (the NQ_Voz doesnt exist).
For OZ V4V5.5 0 and later a similar but more correct window is displayed with "This application requires OZ VX.Y or newer" message if the specified OZ release is newer than what is currently running. , the "OZ version not compatible" message is displayed as a fatal error using a OS_BYE with A unchanged if Fc = 1.
NQ_Roz
Code Block | ||
---|---|---|
| ||
IN: - OUT: DEBC = OZ revision number Registers changed after return: AF....HL/IXIY same ..BCDE../.... different |
Notes:
Used by system information page in Index.
NQ_Btl
Code Block | ||
---|---|---|
| ||
IN: - OUT: Fz = 0, Battery is good Fz = 1, Battery is low Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Notes:
Battery low condition is set when under 4.2V. Coma state is entered by NMI when battery voltage falls under 3.2V.
This call is used by system information page in Index.