Code Block | ||
---|---|---|
| ||
IN: B = record type letter (Name, Creation, Update, eXtent, Efs, Attribute) DE = user buffer address (to store information to be written, always local, in S0 or S1) IX = DOR handle (device or file type) OUT, if call successful: Fc = 0 original IX DOR handle is still valid OUT, if call failed: Fc = 1 original IX is still valid A = error code RC_BAD ($04), bad argument Registers changed after return: A.BCDEHL/IXIY same .F....../.... different |
Note
- This call is the optimized equivalent of DR_WR for file record. It is used by operating itself.
- Read notes about DR_FRR.
Code Block | ||
---|---|---|
| ||
IN: IX = DOR handle OUT, if call successful: Fc = 0 handle or device is NOT already in use OUT, if call failed: Fc = 1 original IX is still valid A = error code RC_USE, already in use Registers changed after return: ..BCDEHL/IXIY same .F....../.... different |
...