Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Panel popdown allows you to set up aspects of the Cambridge Z88's operation to suit your own preferences. You can change the language, alter the rate at which keys on the keyboard, auto-repeat when you hold them down, the time after which the Cambridge Z88 will automatically switch off, the default device and directory used by the Filer, and the parameters for the serial interface.

You call up the panel by typing S (for Settings) or from the INDEX moving the cursor over the Application name and using the key.

Altering the panel

Cursor Keys

To alter an option on the panel, first select it by moving the cursor to the appropriate line with the cursor keys   and . Then type in the new value for the option, and press .

The editing commands are summarised on the Panel CURSOR menu.

In the case of options with alternative values you can also select between the alternatives using

J Next Option

This toggles through all the available options or if you can remember the option you want, typing the option's

First letter or first Capital letter

shown in the word, will select it immediately.

You can save a particular set of panel settings in a panel file, using the Save command on the FILES menu. Selecting the New command on the FILES menu returns the settings to their initial values.

Panel options

For each of the following options the initial default value is shown in brackets.

Keyboard options

Auto-repeat rate (6): 

determines the rate at which keys auto-repeat when held down continuously. Smaller values increase the repeat rate. A value of 0 gives no auto-repeat.

Keyclick (No): 

altering the option to Yes gives an audible bleep at each keypress, to provide additional feedback during touch-typing.

Note
titleNote: + Use these Settings before starting an Application or Popdown

These 3 settings for Insert/Overtype, Default device and Default directory only affect new activities.
When a new Application or Popdown is started, it looks up and uses the values of these options. Existing activities retain their original settings.

Insert/Overtype (Insert): 

in Insert mode text typed at the keyboard is inserted at the cursor position, and subsequent text on the line moves to the right to make space for the new text. Some typists prefer Overtype mode, in which text types over any text previously on the line. To insert text in Overtype mode you need to make a gap in the line with the Insert Character command U first.

Filer options

Default device (:RAM.1 or :RAM.2): 

the device to and from which files are saved and loaded. This is set to the largest RAM found. It can be set to :RAM.1, :RAM.2, or :RAM.3, corresponding to the three RAM cards.

Default directory: 

allows a path of one or more directories, which should already exist, to be specified for all filing-system operations. By default the top-level directory is selected.

Machine options

Timeout (mins) (5): 

determines the time after which the Cambridge Z88 will switch off if nothing is typed at the keyboard; a value of 0 disables timeout. Setting the timeout to 2 minutes will extend the effective battery life of the Cambridge Z88 (1 minute is possible but not recommended for normal use).

Sound (Yes): 

allows the internal sound system to be switched off.

Map (Yes): 

allows the PipeDream page map display to be turned off if not required. Typing and editing will be marginally faster when the map is disabled.

Map size (80): 

allows the size of the map to be altered up to a maximum of 92 characters across, or 255 characters across on an expanded machine. See Expanded/Unexpanded,

Date format (European): 

determines the format for all dates in the Cambridge Z88; the default date format is European, so that dates are recognised in the form:

day/month/year

This option can be changed to American to work with the format

month/day/year.

Keyboard (Uk): 

can be set to any of the following countries using the capital letter of the name:

Uk, France, Denmark, Sweden, Finland, Germany, usA, sPain & Italy.

Changing this option allows the appropriate extra characters to be displayed on the screen, allows a different keyboard to be used and has been covered in more detail previously. See Changing keyboard layout.

Keyboard layouts are shown in the Appendix

Anchor
Serial_port_parameters
Serial_port_parameters
Serial port parameters

Transmit baud rate (9600) / Receive baud rate (9600): 

can both be set to any of the following values:

75, 300, 600, 1200, 2400, 9600, 19200, 38400

The standard Z88 with OZ 3.x and V4.0 could only reach 9600 baud. All speeds can be selected using OZ 4.5.

Parity (None): 

can be set to None, Space, Mark, Odd, or Even. The number of data bits is 8 if None is specified, or 7 otherwise.

Xon/Xoff (Yes): 

determines whether the serial communication protocol uses Xon/Xoff.

The number of start and stop bits is fixed as follows:

Transmit: 1 start bit, 2 stop bits. 
Receive: 1 start bit, 1 stop bit.

Menu Options

Pressing the  key gives the following options.

Cursor

These cursor commands are described above.

Files

 

FL File Load

Loading the Panel's settings

Loads a file that has been saved previously by the Panel. This will set all the parameters in the Panel to the setting that were made when the save was made. The following option is displayed:

Filename

Instead of typing the file name, the file can be selected from the Filer. After typing FL, call the Filer by typing F, and select the required document using the cursor keys followed by  (see Selecting files). You can then return to PipeDream from the Filer by pressing , and the full file name will have been entered for you. Press  to load the file.

FS File Save

Saving the Panel's settings

The following option is displayed:

Filename  

You can save a particular set of panel settings in a panel file, using the Save command on the FILES menu.

FNEW

Reset to initial values

Selecting the New command on the FILES menu returns the settings to their initial values.