Register parameters

Code Block
languagenone
titleRST 20H, DEFW DEFB $3F
IN:
     BC = timeout in 1/100 second ticks
     IX = handle of file (or device)

OUT, if call successful:
     Fc = 0, if byte read OK
     A = byte read
     BC = remaining time in 1/100 seconds
OUT, if call failed:
     Fc = 1
     A = error code:
          RC_EOF ($09), end of file reached
          RC_HAND ($08), bad handle supplied in IX
          RC_RP ($13), device is read-protected
          RC_TIME ($02), if timeout.
          RC_ESC ($01), escape, if device :COM.0, :PRT.0, or :INP.0
          RC_SUSP ($69), if device is :COM.0, :PRT.0 or :INP.0
          RC_DRAW ($66), if device is :INP.0
          RC_QUIT ($67), if device is :INP.0

Registers changed after return:
     ....DEHL/IXIY same
     AFBC..../.... different

...