Test point | Waveform |
---|---|
General | |
R44 | 5.5V sinewave 9.8304 MHz (MCK) NOTE: Before attempting to measure this signal, refer to the CAUTION on page 4.4 |
C18 | 5.2V sinewave 25.6 KHz |
T24 | Collector 5.2V squarwave squarewave 25.6 KHz (SCK) |
C21 | 40 uS reset pulse, negative going (press Reset switch) |
T25 | Collector +5.0V sense line (SNS) |
C14 | +2.4V (LP) |
IC1 | |
Pin 6 | Squarewave 5.5V 3.2768 MHz (Z80 clock) |
Pin 11 | +5.5V |
Pin 16 | Negative going 5.5V pulses, 100 Hz (/INT) |
Pin 17 | Negative going 5.5V pulses, 100 Hz (/NMI) |
Pin 18 | Negative going 5.5V pulses, 100 Hz (/HALT) |
Pin 20 | Negative going 5.5V pulses, 100 Hz (/IORQ) |
Pin 26 | Negative going reset pulse, (/RST, press Reset switch) |
Display SK5 | |
Pin 1 | +5.5V |
Pin 3 | -6.6V to -10.5V variable by RV1 |
Pin 4 | +5.5V pulses, 300 nS pulse width, period 156 uS |
Pin 5 | 5.5V squarewave 50 Hz (FR) |
Pin 6 | +5.5V |
Pins 8,11,12,13,14 | Data |
Pin 9 | 5.5V squarewave 3 MHz (display shift clock, XSCL) |
...