GN_Pmd, Put (set) the current machine date
Register parameters
RST 20H, DEFW $1C09
IN: HL = 0, not allowed HL = 1, not allowed HL = 2, 3 byte internal date in ABC (A = high byte, C = low byte) HL > 255, HL points to 3 byte internal date (low byte first) OUT, if call successful: - Registers changed after return: AFBCDEHL/IXIY same ......../.... differentÂ
Notes
The date is used throughout the machine and should only be altered if the user of the machine is fully aware of the fact. Flow sequence:Â
- Get real time in days/seconds/centiseconds
- Reset RTC
- Multiply set-days by $011580
- Add real seconds
- Save new base seconds
Related calls
GN_Dei, convert zoned format date to internal format
GN_Die, convert internal format date to zoned format
GN_Gdt, convert an ASCII string to an internal binary date
GN_Gmd, Get (read) machine date in internal format
GN_Pmt, Put (set) machine time
GN_Pdt, write internal date as ASCII string