OS_Ploz, Poll for running OZ
Register parameters
RST 20H, DEFW $C606
IN: A = slot number (0 to 3) OUT, if call successfull: Fz = 0, OZ is running in slot Fz = 1, OZ is not running in slot. OUT, if call failed: Fc = 1 A = RC_ONF, no card found Registers changed after return: A.BCDEHL/IXIY same .F....../.... differentÂ
Notes
OZ can only run in slot 0 or 1. Using this call for slots 2 and 3 will always return Fz = 1. This call is used internally by OZ in the Flash card management sub-system, when it is necessary to turn off the screen during Flash hardware operations on the same card as a running OZ. Applications may benefit from this system call too.
This system call is only available in OZ release 4.2 and newer.
Related calls
DC_Pol, poll for card usage
OS_Poll, poll for an application
OS_Use, process card usage